Rheem Tankless Water Heater RTG-53 Indoor/Outdoor - Natural Gas/Propane
 |
- Continuous hot water
- Energy efficient design, no storage tank to keep hot
- Electronically controlled - 120V, 60Hz single phase
- Low NOx emissions
- Self-diagnostic program
- Digital display remote
- Exclusive oxygen depletion sensor - checks the exhaust gas to see how
clean the unit is burning so the unit can adjust the sensing burner for a
cleaner burn.
- Exclusive film wrap overheat limiter - monitors the temperature of the
heat exchanger and will shut the unit down if it exceeds a safe
temperature. It also checks for a lack of oxygen - if detected, the unit
will shut down.
- Built-in electric blower
- Indoor units use Category III stainless venting
- Indoor models supplied with a 120 volt power cord
- Low NOx emissions meet SCAQMD rule 1146 requirements
- A USC1-117 waterproof remote control is included with all RTG-74
models (maximum setting: 120F)
- Optional remote control UMC-117 has a maximum setting of 140F.
- Manufacturer's 10 year limited warranty on heat exchanger, 3 year
limited warranty on parts
|
FREE SHIPPING
Free Shipping in Continental USA
Specs
| DESCRIPTION |
FEATURES |
ROUGHING IN DIMENSIONS
(shown in inches) |
| Model # |
Gas
Input
BTU/Hr. |
Type |
Temp.
Range* |
GPM @ 77
Rise Max. |
GPM @ 45
Rise Max. |
Water
Conn. |
Gas
Conn. |
Height |
Width |
Depth |
Vent
Diameter |
RTG-53PVN
(Nat. Gas) |
21,600 - 145,000 |
Indoor |
100 to
140F |
3.1 |
5.3 |
3/4 |
3/4 |
20 1/2 |
13 3/4 |
5 1/4 |
3 |
RTG-53PVP
(LP Gas) |
21,600 - 145,000 |
Indoor |
100 to
140F |
3.1 |
5.3 |
3/4 |
3/4 |
20 1/2 |
13 3/4 |
5 1/4 |
3 |
RTG-53XN
(Nat. Gas) |
21,600 - 145,000 |
Outdoor |
100 to
140F |
3.1 |
5.3 |
3/4 |
3/4 |
20 1/2 |
13 3/4 |
5 1/4 |
N/A |
RTG-53XP
(LP Gas) |
21,600 - 145,000 |
Outdoor |
100 to
140F |
3.1 |
5.3 |
3/4 |
3/4 |
20 1/2 |
13 3/4 |
5 1/4 |
N/A |
RTG-53 MANUAL PDF
INDOOR MODEL SPEC SHEET PDF
Energy Factor: .82
Flow Rate @ Temp Rise:
-
@45:
5.3 GPM
-
@50: 4.7 GPM
-
@60:
3.9 GPM
-
@77: 3.1 GPM
-
@90: 2.6 GPM
Q - "How much hot water must be flowing before the tankless water
heater turns on?"
A. The minimum flow to operate these tankless water heaters is
0.66gpm.
Q "What is the minimum amount of water pressure needed for
these to operate?"
A These units require a consistent 14psi or
better water pressure to operate.
Q " What water pressure is needed for
supplying hot water to upper floors?"
A To supply water to upper floors, you'll need an
additional 0.44psi/ft of water pressure. Basically, for every one vertical foot,
you'll need an additional 0.44psi of water pressure.
Q "What water pressure is recommended for well water?"
A Well water systems should be set at a range of 50-60psi.
Easy as
1-2-3" Tankless Selection
Contrators' Brochure
If your home has 1 bathroom, a Rheem tankless RTG2-42 series water heater
should provide an ample supply of continuous hot water. If your home has 1-2
bathrooms, you should consider a Rheem RTG-53 series water heater. For up to 3
bathroom homes, the larger Rheem Tankless RTG-74 series water heater should be selected. For
homes with more than 3 bathrooms, large volume demands for hot water, or hot
water circulating systems, you should choose our Rheem TanklessGT-199 heavy-duty water
heater. In some applications, our heavy-duty tankless water heaters are linked
together in a manifold configuration to meet the higher volume demands for
continuous hot water. In fact, up to 20 heavy-duty models can be linked together
to work as one water heating system where only one remote control and manifold
controller are required a Rheem Tankless Water Heater exclusive.
The chart below shows our easy as 1-2-3 selection
guide. If you are unsure which Rheem Tankless Water Heater model is the best for you, we can help.

Rheem's heavy duty tankless water heaters can
supply enough hot water for any commercial use, plus they qualify for
federal
tax credits for energy efficiency.
Rheem Tankless Water Heater
Features
-
Qualifies for $300 Government Tax
Credit
- Continuous hot water
- Energy saving design
- Compact, space saving design
- Intelligent electronic controls and
sensors
- Self diagnostic program
- Digital display shows temperature
setting and maintenance codes
- Exclusive sensing burner technology
- Exclusive film wrap overheat limiter
- Built-in electric blower
- Indoor units use Category III
stainless steel vent
- Low NOx emissions meet SCAQMD rule
1146 requirements
- Indoor models supplied with a 120
volt power cord
- Factory set maximum temperature is
120 F.
- For installations above 3,280 feet a
high altitude chip is required. Refer to Rheem price list or consult factory
for details.
-
10-Year Limited Warranty on Heat
Exchanger
-
3-Year Limited Warranty on Parts
Rheem Pamphlet
| Have a question? |
| General Information |
 |
 |
|
1-888-758-6270 for Lake County Pipe Support
1-866-720-2076 for Rheem Direct
Available between 7AM - 7PM Central Time
7 days a week |