Venting Your Rheem Tankless Heater

rheem tankless heaters online, rheem tankless heater, rheem tankless, ridgid rools

Venting Your Tankless Heater

Contrators' Brochure

All indoor tankless gas water heaters must be vented vertically or horizontally to the outdoors using Category III stainless steel venting material (No other venting material is permitted). RTG-42PV indoor models require 3" stainless steel venting. RTG-74PV and GT-199PV indoor models require 4" stainless steel venting. Venting details, including clearances and diagrams, can be found in the "Use & Care Manual" of Rheem indoor tankless water heaters. NOTE: Rheem outdoor tankless water heaters do not require venting materials.

When choosing an indoor location, you should consider the shortest venting distance to the outdoors. Consult your professional installer or contact us for maximum venting distances.

Rheem offers all necessary venting materials, accessories and expertise to make your tankless water heater installation easy - including horizontal vent kits listed below.

Vent Kits for Horizontal Venting

Rheem horizontal vent kit (RTG20003) for RTG-42PV series indoor gas models includes:

  • (1) Adapter
  • (2) 90 degree elbows
  • (1) 12" length vent pipe
  • (1) Two-piece 6" - 19" adjustable length pipe
  • (1) Two-piece horizontal wall thimble
  • (1) 90 degree termination elbow with vent screen
  • (1) Pressure relief valve

Venting diagrams shown are for illustrative purposes only.

Rheem horizontal vent kit (RTG20007) for RTG-74PV and GT-199PV series indoor gas models includes:

  • (1) Adapter
  • (2) 90 degree elbows
  • (1) 12" length vent pipe
  • (1) Two-piece 6" - 19" adjustable length pipe
  • (1) Two-piece horizontal wall thimble
  • (1) 90 degree termination elbow with vent screen
  • (1) Pressure relief valve
  • 18-AWG, 2-conductor thermostat wire for remote control

Rheem horizontal vent kit (RTG20066 ) for RTG-53DV series indoor gas models includes:

  • (1) Adapter
  • (1) 90 degree elbows
  • (1) Horizontal termination
  • (1) 12" length vent pipe
  • (1) Pressure relief valve
  • (1) 18-AWG, 2 conductor thermostat wire for remote control

 Rheeem Horizontal Vent Kit (RTG-20033HHT} for RTG-74DV and GT199DV series includes:

  • Faceplate
  • 1 12" Length - Concentric Pipe
  • 1 Horizontal Termination Adapter
  • 1 Air Intake Tee-Heat Fab
  • 8 Self Tapping Screws

    Rheeem Horizontal Vent Kit (RTG-20032VHT} for RTG-74DV and GT199DV series includes:

     

  • 1 36" Length - 4"/7" Concentric Pipe
  • 1 Vertical Termination Adapter
  • 1 Air Intake Tee-Heat Fab
  • 8 Self Tapping Screws
  • 1 Vertical Outlet Termination

     

    The location of your indoor tankless water heater may require additional venting material.

    The location of your indoor tankless water heater may require additional venting material.

    Lake County Pipe assumes no liability in your instilation.